| microParticles GmbH offers electrolyte-stable research particles | ![]() |
| News | About us | Product Palette | Properties | Applications | References |
|
September 2006 ![]()
Fluorescence micrographs of nominal 1 µm Rhodamine B-labelled PS particles
in 2 n NaCl dispersion |
microParticles GmbH offers electrolyte-stable research particles In medical research, microfluidics, and other applications, agglomeration of tracer particles or their sticking to the walls of channels, vessels, or tubes often becomes a problem. Namely in electrolyte solutions, aggregation of conventional polymer particles may hinder experiments severely. microParticles GmbH now succeeded in overcoming such difficulties with PS (polystyrene) and PMMA (poly(methyl methacrylate)) particles by PEG (poly(ethylene glycol)) modification. The particles bear a special permanent PEG coating, anchored in the particle surface. They are colloidally stable even in 2 n NaCl solution. The custom-made particles come either untagged as 5 wt.-% or fluorescently labelled as 2,5 wt.-% aqueous dispersions. They possess the following features:
| |||
|
Back to microParticles homepage
|
|
July 2006 ![]()
|
Successful reassessment of microParticles GmbH according to DIN EN ISO 9001:2000 MicroParticles GmbH has established a DIN EN ISO 9001:2000-conform Quality Management System (QMS) for several years. The QMS serves as a tool to secure all quality-relevant processes in the company and to put into practice our business objectives
According to the audit scheme, TÜV Rheinland Berlin Brandenburg conducted the DIN EN ISO 9001:2000 reassessment of microParticles GmbH on July 04 and 05, 2006. The reassessment covered all business areas of the company, such as research and development, production, logistics, purchasing, and accounting system. As a result, microParticles GmbH was attested to have an effective Quality Management System in place. The auditing yielded that all relevant measures, meant to meet the quality metrics, have been put into action and are maintained at a high level. It emphasized the implemented Failure-Mode-and-Effects-Analysis (FMEA) for process optimization, risk assessment, and effects analysis being an effective instrument to guarantee high product quality and customer satisfaction in the future. Being confronted with toughened competition and an increasing demand for innovations, we consider FMEA a decisive factor for success and good corporate image. | |||
|
Back to microParticles homepage
|
|
April 2006 ![]()
|
Multifunctional superparamagnetic polystyrene particles MicroParticles GmbH now offers to its customers a series of monodisperse superparamagnetic polymer particles with well defined diameters. In addition to plain magnetic particles and magnetic particles with COOH-modification (COOH >100 µmol/g), we supply magnetic beads with streptavidin coating (binding capacity: 400-1200 pmol FITC-biotin/mg). Outstanding properties of the new magnetic microspheres of microParticles GmbH are:
These particles are excellent tools for separation and purification of DNA, proteins, or other biotinylated biomolecules, and in several immunoassays. Rapid, efficient, and gentle separation from the surrounding media is possible via an external magnetic field which can be applied just by a permanent magnet. | |||
|
Back to microParticles homepage
|
|
March 2006
|
New analytical service of microParticles GmbH With immediate effect, microParticles GmbH provides high quality services in characterization of particulate materials in the nano- and micrometer size range. Particle characterization in suspensions or powders includes measurements of particle size, particle size distribution, particle number, and particle shape as well as determination of surface chemical properties like surface charge, functional groups, electrophoretic mobility resp. Zeta potential. Techniques and measuring equipment in our newly established analytical lab comprise:
Don't hesitate to discuss your questions and problems on particle-related issues with us - We would be pleased suggesting solutions for you. | |||
|
Back to microParticles homepage
|
|
January 2006
Mixture of 7 highly monodisperse nanoscale particle size standards measured with a CPS disc centrifuge (DC-24000)
|
Expanded Line of NIST-traceable Particle Size Standards With the beginning of 2006, microParticles GmbH offers its customers a considerably expanded line of NIST-traceable nanoscale particle size standards. Designed especially for quality assurance and calibration purposes in a variety of particle sizing instruments, the nanometer size standards possess the following features:
The newly available 15 size standards within the diameter range from 100 nm through 1000 nm have been characterized by a high resolution CPS disc centrifuge (DC-24000), photon correlation spectroscopy (PCS), and scanning electron microscopy (SEM). All particle size standards come as 2 % aqueous suspensions in 10 or 15 ml dropper-tipped bottles together with a Certificate of Analysis containing also selected physical data and a graph of the size distribution, and an appropriate Material Safety Data Sheet. Of course our mirometer sized standards remain available to our customers as before.
Back to microParticles homepage
|
| News Archives 2005 News Archives 2003/2004 |
Research- and Development Laboratory |
|